Good to know: the causes and codes below are the ones most often reported in manufacturer guides and repair data. They're general guidance, not a diagnosis of your dryer, and they don't replace an inspection by a professional. Electric dryers run on 240 volts and gas dryers have a live gas line, so when in doubt, unplug it and call a technician.
Four free checks first
- The cycle. Air fluff, no-heat and some delicate settings run cool on purpose. Run a normal or cotton cycle on high heat. ENERGY STAR and heat pump dryers also dry at lower temperatures, so they can feel less hot without being broken.
- The breaker (electric). An electric dryer uses a double breaker. The drum can keep turning on one half while the heating element needs both. Switch the breaker all the way off, then back on. A breaker with one side tripped often still looks on.
- The gas supply (gas). Make sure the shutoff valve behind the dryer is open and your other gas appliances work.
- The airflow. Clean the lint screen. Then go outside while the dryer runs. The CPSC says to check that exhaust air is escaping at the outside vent. The flap should open and you should feel warm air. If not, the vent or duct may be blocked.
What are you seeing?
| What you see | Most likely cause | Who fixes it |
|---|---|---|
| Tumbles, no heat at all (electric) | Half-tripped breaker, blown thermal fuse, broken heating element | Check breaker · parts = pro |
| Tumbles, no heat at all (gas) | Gas valve closed, igniter or gas valve coils | Check valve · parts = pro |
| Stopped heating suddenly | Thermal fuse, often blown by a clogged vent | Pro + clean vent |
| Heats a little, or on and off | Poor airflow, worn cycling thermostat, gas valve coils | Clean vent first |
| Takes 2+ cycles to dry | Clogged lint screen or exhaust duct | Clean vent |
| Shuts off mid-cycle | Overheating | Call a pro |
Why did my dryer stop heating all at once?
A sudden stop usually means a safety part or a heating part has opened its circuit:
- Thermal fuse: a one-time safety part. It blows when the dryer runs too hot and cuts the heat. On some models it stops the dryer entirely. It doesn't reset, so it has to be replaced.
- Heating element (electric): the coil can break, which ends the heat in one go.
- High-limit thermostat: cuts the heat if the dryer overheats. A failed one can stay open.
- Igniter or gas valve coils (gas): if the igniter never glows, or glows but no flame lights, one of these is the usual suspect.
A blown thermal fuse is often a symptom, not the real problem. Dryers usually overheat because hot, damp air can't get out. The CPSC notes that lint can block airflow and cause heat to build up. If the vent stays blocked, a new fuse can blow again.

The vent: the most overlooked cause
The dryer vent is its own system, separate from the dryer. It still needs checking even right after the dryer itself has been repaired. We explain this to customers often.
- The duct behind the dryer: the CPSC says plastic or foil accordion duct traps lint more easily and kinks or crushes. Most manufacturers specify rigid or semi-rigid metal duct.
- The outside flap: NFPA says it should open when the dryer runs.
- Cleaning schedule: NFPA advises cleaning lint out of the vent pipe once a year, or more often if drying is taking longer than normal.
It's also a fire safety issue. NFPA names failure to clean as the leading cause of home dryer fires. The U.S. Fire Administration's report on 2008–2010 data put residential dryer fires at about 2,900 a year, with failure to clean the leading factor in 34 percent of them.
Dryer error codes for heat and airflow, by brand
If your dryer shows a code, write it down exactly. Here's what the common heat and airflow codes mean, mostly according to each manufacturer:
| Brand | Code | What it means |
|---|---|---|
| Whirlpool, Maytag, KitchenAid | AF or F4E3 | Restricted airflow: lint screen or vent clogged, or vent crushed, kinked or with too many turns |
| Whirlpool, Maytag, KitchenAid | F3E1 / F3E3 | Exhaust / inlet temperature sensor (thermistor). Reset power for 1 minute; if it returns, call for service. |
| Whirlpool, Maytag, KitchenAid | F# E# (alternating) | The control has found a problem that needs service |
| GE & GE Profile | "Vent Blocked" light | Reduced airflow from a blocked or restricted vent (on some models). Check and clean the vent. |
| Samsung | hE, HC, HC4, 1HC | Heating error. hE usually means the dryer is getting too hot, most often from a clogged lint screen or vent. |
| LG | d80 / d90 / d95 | Exhaust duct about 80%, 90% or 95% blocked (Flow Sense). On gas models, d80 can also mean a lack of gas. |
| Electrolux & Frigidaire* | E64 / E65 / E66 | Heating faults: E64 heating element, E65 high-limit thermostat tripping too often, E66 thermal limiter (fuse) tripped, often from overheating |
| Bosch | E01 / E02 | Lint filter (or heat exchanger) blocked with lint or fabric softener residue. Clean after every cycle. |
| Miele | F66 | Lint filters, plinth filter or heat exchanger are dirty |
*Electrolux and Frigidaire codes come from repair-parts references (Sears PartsDirect), not an Electrolux support page. All other codes are from the manufacturers' own support pages or owner's manuals. A code on one brand can mean something different on another, and codes vary by model, so always confirm in the manual for your exact model.
Dryer not heating: common problems by brand
Everyday brands
Whirlpool, Maytag & KitchenAid
Repair data points most often to an open heating element, a failed thermal cut-off fuse or a blown thermal fuse. An "AF" or F4E3 code means the dryer has detected restricted airflow, so check the vent first. Whirlpool also sells a dryer vent test kit.
GE & GE Profile
Repair data shows the same top three: the heating element, thermal cut-off fuse and thermal fuse. Some GE models have a "Vent Blocked" light that warns of poor airflow. On gas models, first make sure the gas shutoff valve is fully open.
Samsung
An hE or HC code means a heating error. Samsung says the most common cause of hE is a clogged lint screen or vent trapping heat. Clean both before calling for service.
LG
LG says slow drying or no heat is most often a blocked airflow. The Flow Sense codes (d80, d90, d95) show how bad the blockage is. If the warning stays after the vent is cleaned, LG says the blower fan may be faulty.
Electrolux & Frigidaire
Heating codes in the E6 range (E64, E65, E66) point to the heating element, the high-limit thermostat or a tripped thermal limiter. Repeated E65 or E66 codes usually mean the dryer is overheating, so check the vent before replacing parts.
European and high-end brands
Bosch, Miele and other compact or ventless dryers work differently from standard vented dryers. Heat pump models dry at lower temperatures and feel warm rather than hot. That's normal. Their airflow depends on filters and a heat exchanger you have to keep clean.
Bosch
An E01 or E02 code means a blocked lint filter. Bosch says to clean the lint filter after every use and, on condensation models, empty the water container after each cycle, or the next program can stop. On condenser models, a dirty condenser cuts heat and drying. For a Bosch that truly isn't heating, Bosch US says to contact its customer service.
Miele
An F66 fault or a "Clean out airways" light means dirty lint filters, a dirty plinth filter or lint in the heat exchanger. Miele says not to put the plinth filter back dripping wet, because that can cause a fault.
Whirlpool compact heat pump
Whirlpool notes that slightly longer dry times are normal on its compact heat pump dryers, so check the filters before assuming a fault.
Based on what's most commonly reported for each brand. Your dryer may have a different problem, so always have a professional confirm the cause.
Can I fix it myself?
The cycle, the breaker, the gas shutoff valve, the lint screen and the outside vent are safe for most people to check. Before moving the dryer, unplug it, and on a gas model close the gas valve first.
The thermal fuse, thermostats, element and igniter sit behind panels, have to be tested with a meter with the dryer unplugged, and differ from model to model. Leave the gas valve, burner and gas line to a professional. NFPA advises having gas dryers inspected by a qualified professional to make sure the gas line and connection are intact and free of leaks. And replacing a fuse without fixing the airflow that blew it just sets up the next one.
A quick safety note: If you ever smell gas near your dryer, don't flip switches or use your phone inside. Step outside and call your gas company or 911 from there. If you notice a burning smell, stop the dryer and unplug it once it's safe to reach, then give us a call.
Stop and call a technician if:
- The cycle, breaker or gas supply, and outside airflow all check out, and there's still no heat
- The thermal fuse has blown before, which means something is making the dryer overheat
- The igniter glows but no flame lights, or the flame goes out
- You notice a burning or hot electrical smell. Stop using it and unplug it.
- The dryer shuts off partway through a cycle, which can mean it's overheating
What does dryer repair cost?
We charge an $89 diagnostic fee, credited toward the repair if you go ahead. We don't quote over the phone. You get the full repair price after the diagnosis and before any work starts.
Have ready when you call:
- The brand and model number, on a label around the door opening or on the back
- Gas or electric, and whether the drum still turns
- Whether there's any heat at all, and any code on the display (write it down exactly)
- When the vent was last cleaned
Quick FAQ
Why is my dryer running but not heating?
Check the cycle, the breaker or gas valve, and the outside vent first. If those are fine, it's usually a blown thermal fuse, the heating element (electric), or the igniter or gas valve coils (gas).
Why does my dryer keep blowing the thermal fuse?
Almost always overheating from a clogged vent. Clean the whole vent run, not just the lint screen, or the new fuse can blow too.
Is it normal for my heat pump dryer to feel less hot?
Yes. Heat pump dryers run at lower temperatures and take a little longer. Keep the filters clean.